Object 605Ah: Quick stop option code (DS402)

This object defines the action, which is taken as quick stop function.

Index

605Ah

Name

Quick stop option code

Object code

VAR

Data type

INTEGER16

Category

optional

Access

R/W

PDO mapping

not possible

Value range

1, 2, 5, 6

Default value

2

Supported codes:

Bit

Description

1

Slow down on slow down ramp and transit into Switch On Disabled

2

Slow down on quick stop ramp and transit into Switch On Disabled

5

Slow down on slow down ramp and stay in Quick Stop Active

6

Slow down on quick stop ramp and stay in Quick Stop Active